Let's talk about your next study New study? Request a quote →
Loading...
RNA Therapeutics Bioanalysis

RNA Therapeutics Bioanalysis

Pharmacodynamic, biodistribution, and immune readouts for mRNA, siRNA, and antisense oligonucleotide programs, from preclinical models through clinical trials

An RNA therapeutic does its work only after it is delivered to a cell, so the measurements that decide a program are rarely the concentration of the drug substance. What matters is what the molecule does once it arrives: how much reaches each tissue and for how long, whether the encoded protein is made or the target transcript knocked down, and whether the formulation trips the innate sensors that detect foreign RNA. These are different questions with different readouts, and the answers that look interchangeable are not. A payload copy number is not evidence of expression, and a knockdown measured in blood is not knockdown in the tissue the drug must reach.

Accelevir measures what an RNA therapeutic does, across messenger RNA, self-amplifying and circular RNA, siRNA, and antisense oligonucleotide (ASO) programs. We design each digital PCR assay around the therapeutic itself: where an oligonucleotide directs cleavage of its target, how a codon-optimized transcript is told from the host gene it resembles, and which cells took up and translated a payload. The molecular, expression, and immune readouts run in one laboratory on material from a single collection, so delivery, activity, and the response to the formulation are read against each other rather than assembled from separate vendors. The same methods and the same team carry a program from preclinical studies into clinical trials. Assays supporting clinical trials are analytically qualified under our quality management system, with qualification documentation available to support regulatory filings.

These readouts serve mRNA vaccine programs too, where the encoded antigen and the immune response to it are the endpoint rather than a liability, and that work is described on our vaccine immune response testing page.

Delivery and Distribution: Where the Payload Goes

We quantify mRNA payload in plasma and tissue by reverse-transcription digital PCR (RT-dPCR). Results can be reported as copies per microgram of input RNA, per cell input into the extraction, per volume for a liquid sample, or as a combination, and we settle the unit with you against the endpoint it has to serve. Resolving the payload tissue by tissue and timepoint by timepoint shows where a lipid nanoparticle delivered its cargo and how quickly each tissue cleared it, which a plasma measurement cannot, because the organ that matters is often not the one the drug circulates in. The study design, including the tissue panel and the sampling schedule, sits on our biodistribution studies page, and the assay design on our digital PCR page.

For a self-amplifying construct the same assay answers a different question, because the payload replicates after delivery, so the quantity in a tissue reflects both what arrived and what the construct made of it.

Expression: Transcript and Encoded Protein

For an mRNA therapeutic, the delivered message is quantified as transcript by RT-dPCR, and the design problem is specificity. A therapeutic transcript often copies a gene the cell already expresses, so an assay that cannot tell the two apart reports the sum of both. We place the assay where the construct differs from the endogenous gene: the codon-optimized coding sequence, the non-native untranslated regions, or the junctions between them. Where a construct shares its coding sequence, the distinguishing sequence is a tag or other non-native element designed into the drug, and the assay is anchored there.

One property of an RT-PCR readout is worth stating plainly. The assay counts molecules carrying the amplicon it targets, so it reports the abundance of that region rather than of full-length, translatable message. Resolving full-length mRNA is limited by the long reverse transcription step it would require, a constraint of the chemistry rather than of assay design, and the field has not established how much the distinction changes an interpretation in vivo. Where confirming translation matters more than refining the transcript number, a protein readout is the more direct answer.

We can also read the encoded protein as an exploratory expression readout. We measure a secreted product by ELISA on plasma or serum, and an intracellular or membrane product by flow cytometry, each set up for the program and read against transcript from the same samples. Distinguishing the encoded product from an endogenous or residual form of the same protein depends on there being a difference an antibody can resolve, such as a tag or a sequence the endogenous protein lacks. Where no such difference exists, transcript remains the specific readout and protein is interpreted as a total.

Expression: Transcript and Encoded Protein

Knockdown and Splice Switching: siRNA and ASO Pharmacodynamics

For an siRNA or an ASO, the pharmacodynamic (PD) readout is what the oligonucleotide did to its target, and we measure it two ways depending on the mechanism. A gene-silencing oligonucleotide reduces the target transcript, which we quantify by RT-dPCR. A splice-switching oligonucleotide redirects splicing instead, so we measure the isoform it was designed to produce.

Getting a knockdown number right depends on where the assay reads relative to where the drug acts. An siRNA loaded into RISC directs cleavage of its target at a position set by the 5′ end of the guide strand, and a gapmer ASO recruits RNase H1 to cut within the DNA-RNA duplex it forms. In both cases the oligonucleotide directs the cut rather than making it, and the cleaved transcript is left in pieces. An amplicon placed across or near that site can therefore report a different result from one placed well away, so we design each assay with the cleavage or binding site in mind and scope the amplicon placement with you.

That a knockdown number depends on the assay is not a theoretical worry. RT-qPCR readouts have been reported in Nature Biotechnology to substantially overstate knockdown by RNA-targeting systems, through interference with the measurement rather than any effect on the target. Where a decision rests on the result, we can confirm a knockdown against an independently designed transcript assay, or against a protein or functional endpoint. Which confirmation is the right one, and how readily it can be built, depends on the therapeutic and the application, and we scope it rather than apply one rule.

For a splice-switching oligonucleotide the readout is isoform-specific by design. A total-transcript measurement can be unchanged while the therapeutic is working exactly as intended, because the oligonucleotide alters which exons are retained rather than how much message is present. We build a spliceform-specific assay around the junction the oligonucleotide redirects, and report the targeted isoform against the untargeted form or the total, so the result describes the switch rather than the abundance.

Where the target tissue cannot be sampled, a circulating protein or a transcript from an accessible compartment stands in for it, and what that surrogate can and cannot support is a question we settle in the design rather than after the data arrive.

Innate Immune Activation

Foreign RNA and the particles that carry it can be sensed by the innate immune system, and the question arises for every platform on this page. It is why modified nucleosides were adopted for therapeutic mRNA, work established by Karikó and Weissman, and why synthetic siRNAs are screened for immunostimulation and modified to reduce it. A self-amplifying construct raises it twice over, since the replicating intermediate is itself a sensing substrate. We read innate activation from the cells themselves rather than from a single soluble marker. After exposing peripheral blood mononuclear cells (PBMCs) to the formulation ex vivo, we count the cells secreting IL-1β, IL-6, or TNF-α by FluoroSpot, and assign the response to a cell type by intracellular cytokine staining. We can also measure a panel of interferon-stimulated gene transcripts from blood by multiplex RT-dPCR, since a type I interferon signature is a common consequence of sensing foreign RNA, and a study can include a broader systemic cytokine measurement alongside these readouts.

The ex vivo exposure screens what a formulation is capable of provoking, and the transcript and systemic readouts describe what happened in the animal or the participant. Reading activation from the cells ties an inflammatory signal to the cells producing it and to the formulation behind it, which a concentration in plasma does not.

Innate Immune Activation

Which Cells Took Up the Payload

Which Cells Took Up the Payload

Delivery is rarely uniform across the cells of a tissue, because a lipid nanoparticle’s composition, not only the organ it reaches, decides which cells translate its cargo. A bulk measurement averages over populations that may have received very different doses, so a question about targeting is a question about cell types. Isolating the intended target population and the populations the formulation was meant to spare, then quantifying payload or transcript in each fraction, answers it directly: delivery is attributed to a cell type rather than inferred from a tissue average.

Immunomagnetic selection resolves a population defined by the presence or absence of surface markers, which covers most of what a study needs and runs in a closed system across a cohort. Where a population is defined by a marker combination, an expression level, or an intracellular target that selection cannot resolve, we move the work to multiparameter sorting, with our scientists defining the sort logic and gating and attending the sort. A construct carrying a fluorescent reporter is the clearest case for sorting, since the reporter marks the cells that received and expressed the payload and no antibody addresses it. Neither route is better in general, and the right one follows from how the population is defined and what the endpoint will tolerate.

The Immune Response to an Encoded Protein

An mRNA can encode a protein the host immune system treats as foreign, and a response can then form against it. That is the case for a replacement protein in a participant who makes none of their own, and it can change how the drug behaves on repeat dosing. The useful picture comes from reading several assays against each other rather than any one of them.

ELISpot and FluoroSpot count how many cells respond to the encoded protein, and FluoroSpot shows how many of those cells carry more than one function at once. Intracellular cytokine staining assigns each response to CD4+ or CD8+ T cells and their memory subsets, so a frequency becomes a description of which cells responded and what they make. Antigen-induced T cell proliferation asks whether those cells can expand on re-encounter, a capacity that can be lost while cytokine production persists. Antibody against the encoded protein, measured by an assay built for that protein, completes the picture on the humoral side. Run together on one collection, they separate a response that is large but narrow from one that is smaller and more durable, which is the distinction that matters when a program is deciding whether to redose.

RNA Therapeutics Bioanalysis by Modality

An RNA therapeutics program measures four things: delivery, expression or knockdown, innate activation, and the response to an encoded protein. Which of them carries a decision depends on the modality.

Modality What the measurement has to answer
mRNA for protein replacement
Where the payload reached and for how long, whether the transcript was expressed and told from the endogenous gene, whether the encoded protein appeared, and what the formulation provoked
Antibody-encoding and immunomodulatory mRNA
Payload distribution, expression of the encoded protein over time and on repeat dosing, and the innate and adaptive responses, kept distinct
Self-amplifying and circular RNA
Payload and its persistence, which for a self-amplifying construct reflects replication as well as delivery, so the schedule follows how long expression lasts
siRNA
Knockdown of the target transcript, measured against the cleavage site and confirmed where a decision rests on it, its durability across the dosing interval, and the innate response
Antisense oligonucleotide
Knockdown for a gapmer, or the isoform ratio for a splice-switching oligonucleotide, with an accessible compartment standing in where the target tissue cannot be sampled
Two neighboring programs use many of the same assays toward a different end. Where an mRNA reprograms a cell and the engineered cell is the product, the readouts sit with cell therapy. Where a construct encodes an editor and its guide, they sit with gene and RNA editing. An Accelevir scientist will say at scoping which of them fits your program.

Samples and Species

Samples and Species

The core inputs are plasma or serum and tissue for the molecular and expression readouts, and fresh or viably cryopreserved PBMCs for the immune readouts. We work with human, non-human primate (NHP), and mouse samples, with rat added for the molecular readouts, and the species available depend on the readout. Animal work runs at the vivarium of your choice, and the samples are tested in our laboratory. We isolate and cryopreserve PBMCs from whole blood with rapid-turnaround processing on receipt, and process tissue and isolate nucleic acids in the same laboratory, so one collection can serve several readouts.

For the host response we are also launching total RNA sequencing and messenger RNA sequencing, where a transcriptional profile shows what a formulation provoked beyond the analytes a targeted panel measures, and we can scope it into a biomarker program.

How an RNA Therapeutics Program Runs With Us

01

Scoping

02

Assay design and qualification

03

Testing

04

Reporting

Scoping

An Accelevir scientist works through the modality and formulation, the target gene or encoded protein, the species and stage, and the decision the data has to support. Most programs need more than one readout, so what comes back is a testing plan rather than an assay: the molecular, genomics, and immunology work that answers the question, which samples each readout draws on, and where one collection can serve several. Because those capabilities sit in one laboratory, the plan is built around the biology rather than around what a single platform can reach.

Assay design and qualification

We design each molecular assay around the construct or target, choosing where it reads and which chemistry it uses, and qualify it in the study matrix before testing study samples. Immune assays are qualified for the antigen, species, and sample type the same way.

Testing

We quantify payload, transcript, knockdown, or isoform by digital PCR and run the immune readouts from the same collection, checking controls on every analytical run.

Reporting

You receive results in each readout's units, the controls and quality-control documentation behind them, and tables linking the molecular and immune results by animal or participant and timepoint. The scientists who ran the work are available to go through them with you.

Our Laboratory and Scientific Team

Accelevir is a bioanalytical contract research laboratory in Baltimore, Maryland, built around measurements where the signal of interest is rare and the material finite. An RNA therapeutic raises that kind of measurement: a payload spread thin across a tissue, a transcript that has to be told from the gene it resembles, and a knockdown read against a shifting background. Accelevir has supported more than 100 clinical studies, dozens of them interventional clinical trials, and serves seven program areas: Cell Therapy, Gene Therapy, Gene & RNA Editing, RNA Therapeutics, Vaccines, Antibody & Bispecific Therapeutics, and Antivirals.

We support clinical trials under the comprehensive quality management system of our CAP-accredited, CLIA-certified laboratory, a system CAP inspects as part of our accreditation. Our digital PCR and immune assays run within it under documented standard operating procedures, and we host sponsor audits. All samples are processed in our BSL-2+ laboratory, which adds enhanced biosafety practices to BSL-2 containment for work with bloodborne pathogens and viral vectors.

We coordinate sample shipments from clinical sites and in-life partners, and we receive and track every sample under our quality management system. A chain-of-custody record follows each sample from receipt, and quality assurance reviews every report before it reaches you. Data transfer follows specifications built to your requirements, with the format and schedule agreed before the first samples arrive.

Accelevir is scientist-run. One team works alongside yours from assay design to final report, so a study can adapt as the biology develops, and you have direct access to the scientists running your samples.

About Accelevir

Molecular, genomics, and immunology in one plan

Delivery, expression, knockdown, and the immune response are designed together and run on material from one collection, so a program is not splitting limited sample across vendors or reconciling datasets that were never meant to be read together.

Assays designed around the mechanism

We place an assay where the therapeutic acts, whether that is the cleavage site an oligonucleotide directs or the sequence that separates a construct from the gene it resembles.

Preclinical to clinical in one laboratory

Moving a method from a preclinical vendor to a clinical laboratory can mean requalifying it mid-program. We partner with the vivarium of your choice, then carry the work into analytically qualified testing for clinical trials in the same laboratory.

Talk with our scientific team

FAQ

Frequently Asked Questions

What is RNA therapeutics bioanalysis?

RNA therapeutics bioanalysis is the measurement of what an RNA drug does in a biological sample, rather than of the drug’s own concentration. It covers where the payload distributes, whether the encoded protein is expressed or the target transcript knocked down, and how the immune system responds. Accelevir provides these readouts for mRNA, siRNA, and antisense oligonucleotide programs, by digital PCR, flow cytometry, and spot-based assays.

How do you tell a therapeutic mRNA apart from the endogenous transcript?

Accelevir places the digital PCR assay where the therapeutic sequence differs from the gene the cell already expresses, in the codon-optimized sequence, the non-native untranslated regions, or their junctions. Where a construct shares its coding sequence, we anchor the assay in a tag or other non-native element designed into the drug. We settle the design from your construct sequence at scoping, so the count reflects the therapeutic rather than the background.

What do you measure for an siRNA or an antisense oligonucleotide program?

Accelevir measures what the oligonucleotide does to its target. For a gene-silencing oligonucleotide that is knockdown of the target transcript by RT-dPCR, with the assay designed around where the drug directs cleavage. For a splice-switching oligonucleotide it is the isoform the drug was designed to produce, measured by a spliceform-specific assay built around the junction it redirects. We also read the innate response to the oligonucleotide itself.

How do you know a knockdown result is real?

Accelevir designs the assay around the mechanism, placing the amplicon deliberately relative to where the oligonucleotide directs cleavage. An amplicon across that site can read differently from one placed away from it. Where a decision rests on the result, we can confirm it against an independently designed transcript assay or a protein or functional endpoint. Which confirmation fits depends on the therapeutic and the application, and we scope it with you.

Can you measure the innate immune response to an mRNA or oligonucleotide?

Yes. Accelevir exposes PBMCs to the formulation ex vivo and counts the cells secreting IL-1β, IL-6, or TNF-α by FluoroSpot, then assigns the response to a cell type by intracellular cytokine staining. We can add a panel of interferon-stimulated gene transcripts from blood by multiplex RT-dPCR, and a study can include a broader systemic cytokine measurement. The question applies to mRNA, self-amplifying RNA, and oligonucleotide programs alike.

What is the qualification status of these assays?

The assays Accelevir runs to support clinical trials are analytically qualified under our quality management system, with qualification documentation available to support regulatory filings. For a digital PCR assay, qualification covers specificity, linearity and dynamic range, sensitivity, precision and accuracy, and matrix interference, each established in the matrix the study will use. Preclinical and discovery-stage work can run as research-use-only when a program does not need qualification documentation.

Match the Readouts to Your RNA Therapeutic

Bring us the modality and its chemistry, the target gene or encoded protein, the species and stage, and the samples and timepoints you have or will collect. Tell us which question your next decision turns on, whether delivery, expression, knockdown, or the immune response to the formulation. Accelevir scientists will recommend a testing plan matched to it, with the sample requirements for each readout, and return an itemized proposal.

Accelevir Diagnostics, LLC is a CAP-accredited, CLIA-certified laboratory. Services are provided for research use in support of clinical and preclinical studies and are not intended for diagnostic, therapeutic, prognostic, or patient-management use.