Let's talk about your next study New study? Request a quote →
Loading...
Our Laboratory and Scientific Team

Vaccine
Immune Response Testing

Antibody and T cell readouts for prophylactic and therapeutic vaccines, from preclinical models through clinical trials

A vaccine is designed to raise two kinds of adaptive immunity, antibody and antigen-specific T cells. Antibodies can neutralize the pathogen or mark it for clearance, and their quality, titer, and persistence in circulation can all contribute to protection. Antigen-specific T cells recognize peptides from the pathogen presented on MHC molecules and expand when they meet the antigen again. CD4+ T cells help cognate B cells produce antibody and secrete cytokines that shape the response, and CD8+ T cells kill infected cells. These effector functions can help clear the infection.

The two arms do not always move together: antibody can wane while protection persists, and for some pathogens protection appears to depend largely on T cells. Those T cells can produce inflammatory cytokines that help resolve infection or regulatory cytokines that dampen the response. A study that reads only one arm, or reads T cells through a single cytokine, can therefore misjudge both the size and the kind of immunity a candidate raised. Accelevir measures both arms for mRNA, viral vector (such as adenovirus or MVA vectors), protein subunit, conjugate, inactivated, and live attenuated vaccines, prophylactic or therapeutic, along with how long each persists and what kind of T-cell response the candidate raised. Two candidates can reach the same titer and still raise very different immunity, so reading both arms gives your program a fuller picture of each response than a titer can, and a firmer basis for choosing among candidates, adjuvants, doses, and schedules.

How to Measure the Antibody and T Cell Responses a Vaccine Elicits

Accelevir scientists break the antibody and T-cell responses a vaccine elicits into five measurements, and few programs need all five at every timepoint:

01

The titer of antigen-specific antibody the candidate raised, and how long it persists.

02

The antigen-specific B cells behind that antibody, including the cells secreting it.

03

The presence and subset (CD4+, CD8+, or both) of antigen-specific T cells, and their expansion after recognizing the antigen.

04

The type of response antigen-specific T cells make, read through the cytokines they produce.

 

05

The generation of cytotoxic T cells able to kill cells presenting the antigen.

Plan your readouts with a scientist

WHO

WHO's guidelines on nonclinical evaluation of vaccines state that nonclinical immunogenicity studies should assess the relevant immune response, for example humoral, cell-mediated, or both. FDA's guidance on vaccines to prevent COVID-19, a recent and more specific example, recommends that nonclinical studies evaluate humoral, cellular, and functional immune responses, including CD4+ and CD8+ T-cell responses, and that Th1 and Th2 balance be assessed in animals vaccinated with clinically relevant doses. Which readouts your program needs depends on the pathogen, the platform, and the stage, and our scientists settle that with you before samples are collected, since every readout added at a timepoint draws on the same serum and cells.

Antibody and B Cell Responses

Antigen-specific antibody titer

Accelevir measures antibody against your antigen by ELISA. We coat the plate with your vaccine antigen and block it, add serum or plasma, wash away unbound material, and detect bound IgG with an enzyme-conjugated, species-specific anti-IgG. Because the antigen, the species, and the matrix differ from one program to the next, we set up and analytically qualify the assay for each one, with qualification covering sensitivity, precision, selectivity, and specificity.

The result is semi-quantitative. We call each sample positive or negative against a cut point, a statistically defined threshold set from a panel of antigen-naive samples. That panel can come from untreated control animals, pre-dose samples, or commercially purchased naive samples, provided there are enough of them for the statistics to hold. We then serially dilute positive samples to an endpoint titer, the reciprocal of the highest dilution whose signal remains above the cut point. A titer is a relative measure, comparable within a study run on one method, and where a reference standard exists for your antigen, we titrate results against it instead.

We can also develop functional antibody assays, such as virus neutralization or opsonophagocytic activity, for your program on request.

Antibody-secreting and antigen-specific B cells

We count antibody-secreting B cells by ELISpot, reported as antibody-secreting cells per million input cells, and follow antigen-specific B cells by flow cytometry, to show how the B-cell population that immunization produces develops over time.

FluoroSpot Assay CRO: Multiplex Single-Cell Immune Monitoring

T Cell Responses

Most T-cell assays restimulate cells in culture. We isolate PBMCs from blood in our laboratory or receive them cryopreserved, and splenocytes and tissue-derived cells come from animal studies. Our scientists culture the cells with your vaccine antigen or overlapping peptide pools, alongside positive and negative controls and cells from unvaccinated animals or pre-vaccination samples treated the same way, so that a response above that baseline can be attributed to the vaccine. Each of the four questions below has its own readout.

Are antigen-specific T cells present, and are they CD4+, CD8+, or both?

What do they produce when they see the antigen?

Can they kill?

Do they expand?

01

Are antigen-specific T cells present, and are they CD4+, CD8+, or both? We assign responding cells to a subset by multiparameter flow cytometry with lineage and activation markers, and where a defined epitope and a matched allele are available, MHC multimer staining identifies antigen-specific cells directly.

02

What do they produce when they see the antigen? We count the cells secreting a given cytokine by ELISpot, reported as spot-forming units per million input cells, and assign each cytokine profile to CD4+ or CD8+ T cells by intracellular cytokine staining. We measure cytokines released into the culture by ELISA in our laboratory and send multiplex panels to a partner laboratory. The profile carries the type of response: in CD4+ T cells, IFN-γ and IL-2 are characteristic of a Th1 response; IL-4, IL-5, and IL-13 of a Th2 response; and IL-17 of a Th17 response, while IL-10, which several subsets produce, is commonly read as regulatory. A study that reads only IFN-γ and IL-2 sees the first of these and not the others.

03

Can they kill? Our T cell killing assays measure cytotoxicity against target cells presenting your antigen, read by flow cytometry as specific lysis at defined effector-to-target ratios.

04

Do they expand? We measure antigen-induced T-cell proliferation by CFSE dye dilution, following division in response to the antigen by subset and by generation.

Read together with the antibody results, these readouts describe what kind of response a candidate raised, which is the response a challenge study or a clinical endpoint then tests. For therapeutic vaccines against tumor or self antigens, the same readouts ask whether a response was raised in a host that may be tolerant to the antigen, and whether the responding cells can kill.

Where a study calls for it, we analytically qualify flow cytometry and ELISpot methods under our quality management system, with qualification typically covering the cut point, sensitivity, cell seeding density, linearity, and precision, including intra- and inter-plate and intra- and inter-operator variability.

Samples, Species, and the Material You Already Have

The slow part of a vaccine program is the in-life work, immunizing and sampling animals or running the clinical study, and a timepoint that has passed cannot be collected again. Every readout on this page draws on the samples that work yields, and in many programs the material they need already exists in a freezer from a completed study. The core inputs are serum or plasma for the antibody readouts, fresh or viably cryopreserved PBMCs or splenocytes for the cellular readouts, and your antigen or overlapping peptide pools for plate coating and restimulation. Killing assays also need target cells presenting your antigen, and multimer staining needs reagents matched to a defined epitope and allele. Peptide pools can come from a commercial supplier or from you, and we can qualify custom panels.

Negative selection

Species.

We work with human, mouse, and non-human primate (NHP) samples, most often rhesus or cynomolgus macaque for NHP studies, with the species available varying by assay. For animal studies we partner with the vivarium of your choice, and the testing runs in our laboratory. One Accelevir team tests your preclinical and clinical samples in the same assay formats, with reagents and qualification set for each species and matrix.

Sample types.

We accept whole blood, from which we isolate PBMCs before plating, as well as fresh or cryopreserved PBMCs, serum and plasma, splenocytes, and lymph node and other tissue-derived cells. In animal studies, we can process lymphoid tissue alongside blood, so you can read a draining lymph node against the circulating pool. Our scientists can also enrich a defined population by immunomagnetic cell subset isolation in the same laboratory before measuring an endpoint. All samples are processed in our BSL-2+ laboratory, which adds enhanced biosafety practices to BSL-2 containment for work with bloodborne pathogens and viral vectors.

Timepoints and banked material.

Serial PBMC isolation and cryopreservation are part of the same service, so we process and bank cells from baseline, peak, and later visits the same way and can thaw and batch them for testing as your study requires. For multi-site studies, we harmonize PBMC isolation across collection sites. Vials from a finished study can still answer questions, within the limits set by the serum volume available for a dilution series and the viability and recovery of the cryopreserved cells, both of which we measure before committing material to an assay.

Molecular Endpoints

For mRNA vaccines, Accelevir pairs the immune readouts with molecular ones. Our biodistribution studies quantify the mRNA payload in plasma and tissue by RT-dPCR, showing where it went and how quickly it cleared from each tissue. Because these assays and the antibody and cellular assays run in one laboratory, our scientists design them around one sampling schedule and read them against each other.

For any platform, we are also launching total RNA-seq and mRNA-seq of the host response, and we can scope transcriptional profiling into an integrated biomarker program alongside the antibody and cellular readouts.

What These Measurements Do and Do Not Capture

These readouts characterize the immune response a candidate raised, and each limit below is answered by a different study or measurement.

Protection.

Whether a response protects is established in vivo, in animal studies by challenge or by passive transfer of antibody or cells and in clinical trials by clinical endpoints, none of which we run. The readouts here characterize the response those studies test, and they are not a measure of efficacy.

A correlate of protection, except where one has been established.

For most licensed vaccines, antibody in serum or on mucosa provides a correlate of protection; for some, only surrogates are available, and for many pathogens no correlate has yet been established. Which case your program is in is a property of the pathogen and the published evidence rather than of the assay, and it determines what a titer can be claimed to mean.

The response where it resides.

Blood samples the circulating pool, and responses in draining lymph node, spleen, and mucosal tissue may differ from it, so where the question is anatomical, the sample has to be as well. In animal studies, we can process lymph node and spleen alongside blood to read the tissue response directly.

How a Vaccine Program Runs With Us

01

Scoping

02

Assay development and qualification

03

Sample logistics

04

Testing

05

Reporting

Scoping.

An Accelevir scientist reviews the platform and antigen, the species and stage, the samples and timepoints, and the decision the data has to support, then returns a proposed readout panel and an itemized quote.

Assay development and qualification.

We develop and analytically qualify any assay specific to your antigen, usually the antibody ELISA, under our quality management system before testing study samples, with the cut point rule and acceptance criteria fixed in the method. Qualification documentation is available to support regulatory filings, and we match the quality framework to your program's stage, from research-use work in discovery to clinical testing.

Sample logistics.

We coordinate shipping from your vivarium, clinical sites, or in-life partner, and agree the data transfer format with you before the first samples arrive.

Testing.

We run serum and plasma against the qualified method, and we process PBMCs on receipt or thaw them from cryopreserved stocks, check their viability and recovery, and plate them with the agreed stimulation conditions and controls.

Reporting.

You receive titers with the cut point and controls behind them, cellular results in each assay's units, the gating strategy and gated data files where flow cytometry is used, QC documentation, and tables linking antibody and cellular results by animal or study participant and timepoint. Statistical analysis is optional.

Our Laboratory and Scientific Team

Accelevir is a bioanalytical CRO in Baltimore, Maryland, built around measurements where the signal of interest is rare. An antigen-specific population after immunization is one of those: it sits at low frequency among the cells in a sample, and a method that averages across the sample can return a null result for a response that is present. We run the cellular assays on this page, which count or phenotype responding cells one at a time, on that premise.

Accelevir has supported more than 100 clinical studies, dozens of them interventional clinical trials, and serves seven program areas: Cell Therapy, Gene Therapy, Gene & RNA Editing, RNA Therapeutics, Vaccines, Antibody & Bispecific Therapeutics, and Antivirals.

Accelevir is scientist-run, with one team working alongside yours from protocol design to final report, so a design can adapt as the biology develops. You have direct access to the scientists running your samples.

About Accelevir

Antibody and T cell responses in one laboratory.

Splitting serum and cells between vendors can separate two halves of one answer and make the timepoints harder to read together. We run both, so a titer and a cellular result from the same animal or study participant at the same timepoint arrive in one dataset.

Immune and molecular endpoints from one study design.

For mRNA vaccines, we design payload biodistribution by digital PCR alongside the immune readouts, so you read delivery and response on one sampling schedule.

Preclinical to clinical without changing laboratories.

Moving a method from a preclinical vendor to a clinical laboratory can mean requalifying it mid-program. We partner with the vivarium of your choice for mouse and NHP studies, then carry the work into analytically qualified testing for clinical trials in the same laboratory.

Talk with our scientific team

FAQ

Frequently Asked Questions

Do you have an established assay for our antigen?

Not for the antibody readout: we set up and qualify the ELISA for your antigen, because its coating conditions, controls, and antigen-naive panel all depend on the antigen, the species, and the matrix. The cellular assays are different: ELISpot, flow cytometry, intracellular cytokine staining, proliferation, and killing are established methods in our laboratory, and what changes from one program to the next is the stimulation, the panel, and the analytes.

Can you work with samples from a study that has already finished?

Often, yes. The limits are the serum volume available for a dilution series and the viability and recovery of the cryopreserved cells, which we measure before committing material. Tell us what is in the freezer and what you still want to know, and our scientists will tell you what the material can support.

How do you decide what counts as a positive antibody response?

We set the cut point from a panel of antigen-naive samples, using a statistical rule fixed in the method and agreed with you before study samples are tested. We then report positive samples as an endpoint titer or, where a reference standard exists for your antigen, quantify them against it.

Should we measure T cell responses by ELISpot, FluoroSpot, or intracellular cytokine staining?

ELISpot, which gives the frequency of secreting cells, is usually enough when one cytokine carries the question, and FluoroSpot shows whether the same cells secrete several cytokines. Intracellular cytokine staining assigns each cytokine profile to CD4+ or CD8+ T cells and their memory subsets, which makes it the choice when subset identity matters. An Accelevir scientist recommends a format at scoping, and we keep one format across a study’s timepoints.

Do you run the animal study?

No. Immunization, challenge, and sampling happen at the vivarium of your choice or at your clinical sites, and we test the samples. We advise on the collection plan, including which samples to take and how to divide them between the antibody and cellular readouts, and we handle the transfer logistics.

What is the qualification status of these assays?

Assays run in our laboratory to support clinical trials are analytically qualified under the quality management system of our CAP-accredited, CLIA-certified laboratory, with qualification documentation available to support regulatory filings, and they are not run as CLIA tests. We send multiplex cytokine panels to a partner laboratory, so they fall outside this statement.

What turnaround should we expect?

It depends on the number of samples, how many readouts the design includes, and whether we first have to develop and qualify a method for your antigen. We confirm a timeline in writing when we scope the study.

Find Out What Your Samples Can Still Tell You

Bring us the platform and the antigen, the species and the stage, the samples you have or plan to collect and the timepoints they span, which arm of the response your next decision turns on, and whether the material is already banked. Accelevir scientists will recommend a readout panel matched to that question, state the sample requirements for each readout, and return an itemized proposal for your study design.

Accelevir Diagnostics, LLC is a CAP-accredited, CLIA-certified laboratory. Services are provided for research use in support of clinical and preclinical studies and are not intended for diagnostic, therapeutic, prognostic, or patient-management use.